Esiane sɛ ɛhɔ yɛ hyew na ɛhɔ yɛ nwini kɛse wɔ awɔw bere mu nti, ɛsɛ sɛ abantenten a wɔde yɛ onwini a wɔato mu no gyina nhyɛso atitiriw abiɛsa ano:

 
 

ɔhyew a ɛkorɔn-ɔhyew a wɔsɛe no, nsu a wɔkora so ne nsenia a wɔde siw ano, ne ɔhyew a wɔhwɛ so a ɛyɛ pintinn.

 

Sɛ wopaw nnwinnade a ɛfata a, ebetumi asiw unit no ano sɛ "ɛrenhyew dodo" wɔ awɔw bere mu na ama wɔahwɛ ahu sɛ wɔbɛyɛ no a wontwaa mu. Nsɛntitiriw asia a ɛsɛ sɛ wohyɛ no nsow bere a woretɔ ade no wɔ ase haabantenten a wɔde yɛ onwini a wɔatoto muwɔ awɔw bere mu no, wɔde kasa a emu da hɔ kyerɛkyerɛ mu na aboa wo ma woakwati afiri na woakora ɛka so

Closed-circuit Cooling Towers - We Only Make High-efficiency, Energy-saving Ones

1. Bu W’ahiade Ho Akontaabu Pɛpɛɛpɛ na Kwati Nnwinnade a Ɛnyɛ Den

 

Unique Advantages Of Oasis Bingfeng

 

Sɛ worepaw abantenten a ɛma onwini wɔ awɔw bere mu a, ade titiriw no ne sɛ wobebu tumi a ɛdɔɔso a egyina adwumayɛ tebea a ɛkorɔn-ɔhyew so na woagyaw margin a ɛfata.

 

Ma core parameters mu nna hɔ: Kyerɛ nsuo a ɛkɔ mu no hyeɛ, nsuo a ɛkɔ mu no hyeɛ a wɔde asi w’ani so, ne nsuo a ɛkyinkyini no dodoɔ. Sɛ nhwɛsoɔ no, sɛ nsuo a wɔde yɛ adwuma no hyɛn mu wɔ digrii 45 na ɛhia sɛ wɔma ɛyɛ nwini kɔ digrii 35 a ɛsen 100m3/h a, ɛsɛ sɛ saa akontabuo mmiɛnsa yi yɛ pɛpɛɛpɛ.

Paw gyina wet-bulb hyew so: Nsuo a ɛfiri mu ba no hyeɛ a ɛsua koraa wɔ closed circuit cooling tower ≈ mpɔtam hɔ awɔw bere mu wet-bulb temperature + 3℃. Di kan hwɛ mpɔtam hɔ awɔw bere mu nsu-bulb hyew (sɛ nhwɛso no, 28℃) napaw model a ɛma nsu fi mu pintinnwɔ bɛyɛ digrii 31 ; ɛnyɛ sɛ ɛkyerɛ ɔhyew a ɛyɛ daa-ɔhyew data nko.

Hwɛ sɛ margin a ɛdɔɔso: Esiane sɛ adesoa a ɛsakrasakra kɛse wɔ awɔw bere mu nti, paw model a ɛwɔ15%-20%tumi a ɛma onwini foforo a ɛbɛma wɔatumi agyina nnwinnade a ɛrebɔ akwakoraa ne aberewa ne adesoa a ɛkorɔn-a ɛyɛ hyew a ɛkɔ soro ano, a ɛkwati adwumayɛ a ɛnsɛ.

 

 

2. Coil Material Kyerɛ Ɔsom Nkwa Tẽẽ

 

This Cooling Tower Was Custom-built By Oasis Bingfeng For A European Client.

 

Awɔw bere mu hyew a ɛkɔ soro ma nsɛe ntɛmntɛm, na ɛma coil nneɛma yɛ ade titiriw. Sɛ obi paw nea ɛnteɛ a, ɛbɛma nsu no akɔ ntɛmntɛm.

 

Sɛ wopɛ mfiridwuma mu nsu a ɛyɛ mpapahwekwa a ɛnyɛ nsɛe a: Paw dade a ɛnyɛ den coils 304 ma ɛyɛ adwuma a ɛho ka yɛ den.

Sɛ nsuo a ɛyɛ den anaa chloride ion a ɛdɔɔso (sɛ nhwɛsoɔ no, asase ase nsuo, mpoano mmeaeɛ): Yɛ no foforɔ kɔ 316L stainless steel coils so ma ɛtumi gyina nsɛeɛ ne nsenia ano.

Sɛ wopɛ adwumayɛ tebea titiriw (acid-base a ɛyɛ den, nkyene a ɛdɔɔso): Fa titanium alloy coils di dwuma; ntwitwa ɛka so wɔ ha.

Ahwehwɛde foforo: Si so dua sɛ coil nsuo a ɛsen no yɛ 1–2.5m/s. Rate a ɛba fam dodo sɛe ɔhyew nsakrae, bere a ɛkɔ soro dodo ma nhyɛso a ɛba fam - abien no nyinaa nyɛ nea wɔpɛ.

 

 

3. Fans ne Sprinklers: Ade titiriw a ɛbɛma wɔakora ahoɔden so wɔ Awɔw bere mu

 

Oasis Bingfeng Customized Closed-Circuit Cooling Tower For A Chemical Enterprise

 

Fan ne nsu pɔmpɛ di anyinam ahoɔden pii wɔ awɔw bere mu; nhyehyeɛ a ɛnsɛ bɛma anyinam ahoɔden ho ka a ɛboro-budget aba.

 

Variable-frequency fans yɛ adeɛ a ɛsɛ sɛ: Ɛnam sɛ nnesoa gu ahodoɔ wɔ ahuhuro mu nti, variable-frequency fans no ankasa sesa mframa dodoɔ sɛdeɛ nsuo hyeɛ teɛ, na ɛkora so15%-30%anyinam ahoɔden a wɔde toto fixed-frequency fans ho na ɛtew dede so.

Nsuo a wɔde petepete so yie: Paw anti-clog nozzles na hwɛ sɛ nsuo a wɔde petepete so no kata coils no so pɛpɛɛpɛ (coverage rate>=95%) na ɛyɛ nsuo film a ɛdi mũ. Soroɔhyew ma nsu a ɛyɛ hyew no yɛ ntɛmntɛmwɔ awɔw bere mu, na aduru a wɔde petepete nneɛma so a ɛkorɔn{0}}ma ɔhyew a wɔsɛe no no tu mpɔn.

Nsuo a ɛtwetwe nsuo a ɛyɛ papa-a ɛyɛ papa: Sɛdeɛ nsuo a wɔde petepete nsuo mu no yɛ nwini kɛseɛ wɔ ahuhuro mu no, nsuo a wɔde petepete nsuo mu no brɛ nsuo a ɛyera ase, na ɛkora nsuo a ɛboro nnwinnadeɛ a ɛnyɛ den so 10%-20% na ɛtew nsuo ho ka a ɛkyɛ so.

 

 

4. Hyɛ Media ne Casing ma: Durability yɛ Fapem

A Closed Circuit Cooling Tower Cools Down Equipment

 

Bere tenten-a ɛyɛ hyew a ɛkɔ soro wɔ awɔw bere mu no kyerɛ sɛ sɛnea nneɛma a wɔde hyɛ mu ma ne nea wɔde hyɛ mu no kyɛ no nya mfiri nkwa nna so nkɛntɛnso tẽẽ.

 

Fill media: Ɛsɛ sɛ wode PP anaa CPVC nneɛma a ɛko tia ɔhyew a ɛkorɔn-di dwuma sen PVC a ɛyɛ mmerɛw (a ɛnyɛ den sɛ ɛbɛsɛe na asiw wɔ ɔhyew a ɛkɔ soro mu), na ɛhwɛ hu sɛ ɔhyew no bɛkɔ so atra hɔ a enni nsakrae anaasɛ esiw kwan wɔ awɔw bere mu ɔhyew mu.

Casing: Esiane sɛ osu taa tɔ na ɛhɔ yɛ nwini wɔ awɔw bere mu nti, pawmagnesium-aluminium-zincdade a wɔde adura ho a wɔde yɛ mmeae a ɛwɔ asase mu ne dade a ɛnyɛ den 304 a wɔde yɛ mpoano anaa mframa a ɛsɛe nneɛma a atwa yɛn ho ahyia. Ɛsɛ sɛ nkɔnsɔnkɔnsɔn a ɛda adi nyinaa yɛ dade a ɛnyɛ den na amma ansɛe na ɛnyɛ den sɛ wobesiesie.

 

 

5. Nsuo Pa ne Ne Siesie: Tew Di nkoguo so wɔ Awɔw Bere mu

Oasis Bingfeng: A Reliable Choice With 23 Patented Technologies, Serving 1000+ Clients Globally

 

Ɛnyɛ den sɛ awɔw bere mu hyew a ɛkɔ soro ma atɛkyɛ nyin na ɛyɛ mmerɛw. Nsu a ɛnyɛ papa ne nsiesie a ɛnnɔɔso bɛma ɔhyew a wɔsɛe no so atew ntɛmntɛm.

 

Wɔasisi-wɔ nsuo a wɔde yɛ adwuma mu: Fa nhwɛsoɔ a ɛwɔ automatic filtration ne automatic dosing functions di kan de sa nsuo a wɔde petepete so no ho adwuma ankasa, siw scaling ne algae ano, na ɛtew nsaano nsiesie so.

Nsuo dodoɔ ho banbɔ a edi mũ: Fa low-nsuo afiri alarmne mfiri a wɔde to mu ankasa, a ɛho ka sua nanso ɛbɔ nsuo pɔmpɛ a ne bo yɛ den ho ban fi ɔsɛeɛ a ɛyɛ dry-running ho.

Nsiesiei a ɛnyɛ den: Paw mfonini ahorow a ɛwɔ nhyehyɛe a ɛnyɛ den ne hyɛn gyinabea ahorow a ɛdɔɔso a wode bɛhohoro coil no ho ntɛmntɛm na woasesa nozzle wɔ awɔw bere mu, na ɛmma bere a wɔde yɛ adwuma no nyɛ ketewaa bi.

 

 

6. Installation ne After-Sales Service: Mma W’ani Gu Nsɛm So

Combined Flow Closed Circuit Cooling Tower: The Engineering Unification Of Efficiency And Compactness

 

Beae a wɔde besisi hɔ: Mframa a wɔde bɛma ho hia kɛse wɔ awɔw bere mu. Gyae mframa bɛboro mita 1 wɔ mfiri no ho, na mfa mframa a ɛkɔ mu no nnbɛn afasu ho na amma mframa a ɛyɛ hyew asan akɔ baabiara a ɛmma ɔhyew no nkɔ baabiara.

 

Pɔmpɛ a ɛne ne ho hyia: Paw pɔmpɛ soronko a ɛsen kɛse na ne ti sua a ɛne onwini abantenten no nsusuwii hyia na woakwati dede a ɛkɔ soro wɔ adwumayɛ mu, ahoɔden a wɔde di dwuma boro so, ne bere tiaa a wɔde yɛ adwuma.

Pɛda adi wɔ-adetɔn akyi: Kyerɛw warranty bere, mmuae bere, ne spare parts a wɔde bɛma wɔ apam no mu na ama woahwɛ ahu sɛ wobetumi de on-site siesie ama ntɛm sɛ mfiri no ntumi nyɛ adwuma yiye wɔ awɔw bere mu a, a wɔrentwentwɛn ne nan ase sɛ wɔbɛyɛ no.

 

 

Loaded Unit Photographs Closed-Circuit Cooling Tower Ready for Dispatch

 

Tɔfabɔ

 

Nnyinasosɛm atitiriw a wɔde paw nneɛmaabantenten a wɔde yɛ onwini a wɔatoto muwɔ awɔw bere mu no wobetumi abɔ no mua wɔ nsɛm anan mu: bu margin a ɛdɔɔso ma adwumayɛ tebea a ɛyɛ hyew a ɛkorɔn, paw coil nneɛma a ɛko tia nsɛe, fa ahoɔden-saving variable-frequency fans di dwuma, na fa automated water quality maintenance tom. Sɛ wode w’adwene si saa nsɛm yi so, ne beae a ɛfata a wode besisi ne -adetɔn akyi som a wotumi de ho to so a, ɛbɛboa wo ma woapaw awɔw bere-adan a wɔayɛ no onwini abantenten a ɛhwɛ ma ɔhyew a ɛkɔ so yɛ den, ɛhwɛ ɛka so, na ɛyɛ adwuma dwoodwoo wɔ ɔhyew bere no mu.