Dry na ɛyɛ nsu a wɔato mu onwini abantenten .
Ɔhyew a wɔde sesa: nsu a ɛma ɔhyew kɔ mframa mu Ɔhyew .
Control System: sensor, controllers, actuators ne nneɛma afoforo a ɛwɔ mu .
Ɔhyew a wɔde sesa nneɛma: Fins ne light tube a wɔde sesa ɔhyew a wɔde di dwuma .
Shell material: High{0}}Dadeɛ a ɛwɔ ahoɔden .
Evaporative cooling: nsu a ɛyɛ hyew ne ɔhyew a ɛkɔ nipadua no mu na ama nsu no hyew so atew .
Mframa a ɛsen: Fan ne nneɛma a wɔde hyɛ mu ma ɛboa ma mframa no kɔ nipadua no mu .
Nsuo a wɔde sie a ɛho hia: Sɛ wɔde toto abantenten a ɛyɛ nsuo a ɛho tew ho a, nsuo a wɔkora so a ɛkɔduru 30% ~ 70% .
Mmara a ɛyɛ mmerɛw ne nea wɔde di dwuma: Intelligent control system sɛnea ɔhyew ne ɔhyew te, adesoa a ɛyɛ nnam nsakrae a ɛwɔ adwumayɛ kwan so .
Nneɛma a wɔyɛ ho nkyerɛkyerɛmu .
Nneɛma a ɛwɔ structure composition a ɛwɔ dry ne wet closed cooling tower mu:
Ɔfã a ɛyɛ nsu: Nsu a wɔde petepete nsu a ɛyɛ nwini na ɛyɛ nsu a wɔato mu a ɛma onwini no ne mframa no di nkitaho tẽẽ, na ɔhyew no nam nsu a ɛyɛ hyew so (Latent Heat Exchange). Ɔfã a ɛyɛ dry: Dry and wet closed cooling Tower no finned tube heat exchanger, mframa ne dry ne wet closed cooling tower no tube a ɛkyinkyini nsu a ɛkyinkyini tẽẽ (ɔhyew a wɔde sesa nneɛma a ɛyɛ mmerɛw). Nneɛma a ɛtaa ba: Dry ne wet closed cooling tower fans, pumps, control system, ebia wɔ split-level anaa ɔfã-B{4}}afã nhyehyɛe wɔ atifi ne ase.

Adwumayɛ kwan a ɛyɛ dry ne wet closed cooling tower:
Nkyɛmu adwumayɛ: Wɔ ɔhyew/adesoa a ɛkorɔn mu no, ɔfã a ɛyɛ nsu ne ɔfã a ɛyɛ dry no yɛ adwuma bere koro mu ma ɔhyew a wɔsɛe no no yɛ adwuma yiye. Bere-Sharing: Wɔ ɔhyew a ɛba fam/adesoa a ɛba fam mu no, ɔfã a ɛyɛ dry no nkutoo na wɔde yɛ adwuma ma ɛtew nsu a wɔde di dwuma so; Wɔ ɔhyew a ɛkɔ soro kɛse mu no, wɔde ɔfã a ɛyɛ nsu no yɛ adwuma sɛ ade titiriw. Tandem anaa parallel connection: nsuo betumi ayɛ pre-a ɛyɛ nwini denam dry section no so ansa na woahyɛn wet section (Tandem connection), anaasɛ section mmienu no tumi yɛ adwuma wɔ ahofadi mu (parallel connection).
Nsuo a ɛho hia a wɔkora so: Sɛ wɔde toto abantenten a ɛyɛ nsuo a ɛyɛ nsuo a ɛho tew ho a, nsuo a wɔkora so a ɛyɛ dry ne wet closed cooling tower no betumi adu 30% ~ 70%, enti dry and wet closed cooling tower no fata kɛseɛ ma nsuo-afã anaa nnwuma a ɛyɛ den wɔ nneɛma a atwa yɛn ho ahyia mu.

Nsakraeɛ a ɛyɛ adwuma yie wɔ nneɛma a atwa yɛn ho ahyia ho: Dry and wet closed cooling tower's dry section is highly efficient in low-temperature environments, berɛ a nsuo a ɛyɛ nsuo no yɛ ɔhyew a ɛrensɛe wɔ ɔhyew a ɛkorɔn mu, na ɛde adwumayɛ a ɛyɛ den ba afe no mu nyinaa.
Anti-ICING ne ANTI-Asase a ɛyɛ fitaa: Dry and Wet Closed Cooling Tower to ɔfã a ɛyɛ nsu no mu wɔ awɔw bere mu na amma nsu a wɔde petepete nsu so no ankɔ; Dry section ma mframa a ɛyɛ hyew ne nea ɛyɛ nwini no so tew na esiw nsuyiri fitaa ano.
Tags a ɛyɛ hyew .: Dry ne Wet Closed Cooling Tower, China Dry ne Wet Closed Cooling Tower a wɔyɛ, wɔn a wɔde nneɛma ma, adwumayɛbea
You Might Also Like
Send Inquiry .





