akKasa
Closed circuit nsuo a ɛyɛ nwini .

Closed circuit nsuo a ɛyɛ nwini .

Aguade no din: Closed fluid cooler .
Ɔsom asetra: bɛyɛ mfe 10-15 .
Nsuo a ɛredi akɔneaba: bɛyɛ 200 ~ 290m3/h .
Shell dadeɛ a ɛyɛ den: bɛyɛ 2mm .
Evaporation: Mpɛn pii no bɛyɛ 0.54% wɔ nsu a ɛredi akɔneaba no mu .
Yɛ-Nneɛma a ɛkɔ soro: mpɛn pii no bɛyɛ 0.7%~1.5% wɔ nsu a ɛredi akɔneaba no mu .
Nnwuma a Wɔde Di Dwuma: Dadeɛ ne Dadeɛ Nnwuma, Nnuruyɛ Nnwuma, Mfiridwuma Nnwuma, ne nea ɛkeka ho.
Efficiency embodiment: Nsuo a wɔkora so, ahoɔden a wɔkora so, nhyehyɛeɛ a ɛyɛ yie: nsuo a wɔkora so, ahoɔden a wɔkora so, nhyehyɛeɛ a ɛyɛ adwuma yie, ne nea ɛkeka ho.
Descaling Measures: Ɔhyew a wɔde san yɛ nneɛma a wɔde di dwuma de gye ɔhyew a wɔsɛe no, ne nea ɛkeka ho.
Nnwinnade a wɔpaw: Tailor-Wɔyɛɛ no ​​sɛnea adetɔfo ahiade te .
High-efficiency and water saving: ɛnyɛ sɛ wobenya soro-ahoɔden a ɛyɛ adwuma yiye nko na mmom ɛma nsu a wɔkora so no yɛ kɛse nso .
Send Inquiry .

Nneɛma a wɔyɛ ho nkyerɛkyerɛmu .

 

Nsuo a wɔde petepete nsuo mu a ɛwɔ Closed Circuit Fluid Cooler no twe nsuo firi tank a ɛboaboa ano no mu fa spray pump no mu, ɛde nsuo no kɔ ɔhyew exchanger coil a ɛwɔ closed circuit fluid cooler no atifi, petepete no pɛpɛɛpɛ wɔ coil no coil no ani coil cooler fa nozzle no mu, ɛsesa ɔhyeɛ no ne fasuo no fa fan no mu firi fan no mu fa fa fan no mu ba. Wɔde ɔhyew no sesa coil no fasu no fa nsu no mu, na ɔhyew no fi abantenten no mu ba. Wɔsan de nsu a wɔde gu nsu mu a wɔmfa nsu ngu mu no kɔ nsu a wɔboaboa ano no mu denam dehydrator no so ma wohu sɛ nsu a wɔde di dwuma bio no yɛ nea wɔde di dwuma bio.

 

Customer Site Installation of Closed-Circuit Cooling Tower

 

Ahoɔden a wɔkora so tumi a ɛwɔ Closed Circuit Fluid Cooler Spray System mu .
1. Tew evaporation loss, closed circuit fluid cooler nsu a wɔde petepete so no so tew nsu a ɛyɛ hyew a ɛyera esiane ɔdan a wɔato mu nti, na ɛnam so ma nsu no nsɛe. Sɛ wɔde toto abantenten a ɛma onwini a wɔabue ho a, nsu a wɔkora so wɔ Closed Circuit Fluid Cooler mu no yɛ kɛse yiye. Ɛnyɛ sɛ nsu a ɛtɔ gu fam a wɔtew so no so tew no boa ma wɔkora nsu so nko, na mmom ɛtew ahoɔden a wɔde di dwuma ma nsu a wɔde hyɛ mu no so nso.

 

Front View Diagram of Closed-Circuit Cooling Tower

 

2. Ma spraying efficiency no nyɛ papa, denam structureing device a ɛwɔ closed circuit fluid cooler no nhyehyɛe ne ne nhyehyɛe mu, te sɛ nozzles a ɛyɛ adwuma yiye a wɔbɛfa, optimizing the pressure and flow rate of the spraying water, etc., utilization efficiency a ɛwɔ spraying water no mu no betumi atu mpɔn, na wobetumi atew nneɛma a ɛho nhia a wɔsɛe no so. Optimized spraying system wɔ closed circuit fluid cooler mu no betumi ayɛ nea ɛne coil no di nkitaho yiye, na spraying system no betumi ayɛ nea etu mpɔn kɛse na ɛne coil no adi nkitaho yiye. Optimized spray system in closed circuit fluid cooler betumi ayɛ ɔhyew a wɔde sesa ne coil no yiye, ama onwini a ɛyɛ adwuma yiye no atu mpɔn.


3, frequency conversion technology a wɔde di dwuma wɔ closed circuit fluid cooler water pump a wɔde di dwuma wɔ frequency conversion technology mu, sɛnea Closed Circuit Fluid no ahiade ankasa te no betumi ayɛ nsakrae wɔ nsu a ɛsen ne nhyɛso a ɛwɔ nsu a wɔde petepete no mu no mu, na amma ahoɔden a ɛho nhia no ansɛe.

 

Tags a ɛyɛ hyew .: Closed Circuit Fluid Cooler, China Closed Circuit Nsuo a Ɛyɛ Nwini a Ɛyɛ Nwini, Wɔn a Wɔde Ma, Adwumayɛbea

Send Inquiry .